CAN/CSA C22.2 NO. 61010-031A-07 (R2012) PDF

CAN/CSA C22.2 NO. 61010-031A-07 (R2012) PDF

Name:
CAN/CSA C22.2 NO. 61010-031A-07 (R2012) PDF

Published Date:
07/01/2010

Status:
Active

Description:

Amendment 1:2010 to CAN/CSA-C22.2 NO. 61010-031-07, Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (Adopted IEC 61010-031:2002, MOD) (Tri-National standard,

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$99.3
Need Help?
This is the harmonized CSA, ISA, and UL standard for Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. It is the first edition of CAN/CSA-C22.2 No. 61010-031-07, the second edition of ISA-61010-031 (82.02.02), and the first edition of UL 61010-031. This edition of ISA-61010-031 (82.02.02) supersedes the previous edition of ANSI/ISA-82.02.02-1996 (IEC 61010-2-031) published in 1996. This standard is based on IEC 61010-031, first edition (2002) and Amendment 1 (2008).

Scope

This part of IEC 61010 applies to hand-held and hand-manipulated PROBE ASSEMBLIES of the types described below, and related accessories which are intended for professional, industrial process, and educational use. These PROBE ASSEMBLIES are for use in the interface between an electrical phenomenon and test or measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment.

a) Low-voltage and high-voltage, non-attenuating PROBE ASSEMBLIES(type A). Non-attenuating PROBE ASSEMBLIES that are RATED for direct connection to voltages exceeding 33 V r.m.s. or 46,7 V peak or 70 V d.c., but not exceeding 63 kV. They do not incorporate active components, nor are they intended to provide a voltage divider function or a signal conditioning function, but they may contain passive non-attenuating components such as fuses.

b) High-voltage attenuating or divider PROBE ASSEMBLIES(type B). Attenuating or divider PROBE ASSEMBLIES that are RATED for direct connection to secondary voltages exceeding 1 kV but not exceeding 63 kV. The divider function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment to be used with the PROBE ASSEMBLY.

c) Low-voltage attenuating or divider PROBE ASSEMBLIES(type C). Attenuating, divider or other signal conditioning PROBE ASSEMBLIES for direct connection to voltages exceeding 33 V r.m.s or 46,7 V peak or 70 V d.c., but not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment intended to be used with the PROBE ASSEMBLY.

d) Low-voltage attenuating and non-attenuating PROBE ASSEMBLIES(type D), that are RATED for direct connection only to voltages not exceeding 33 V r.m.s., or 46,7 V peak, or 70 V d.c., and are suitable for currents exceeding 8 A.

NOTE PROBE ASSEMBLIES which
- are not within the definitions of types A, B, C, or D, or
- which are designed to be powered from a low-voltage mains supply, or
- include other features not specifically addressed in this standard may also need to meet the relevant requirements of other parts of IEC 61010 [6]1)
File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 66
Product Code(s) : 2420744, 2418491, 2420744
Published : 07/01/2010

History


Related products

CAN/CSA E335-2-40-94
Published Date: 04/01/1994
Safety of Household and Similar Electrical Appliances - Part 2: Particular Requirements for Electrical Heat Pumps, Air Conditioners and Dehumidifiers (Based on IEC'S second edition) and Canadian Deviations (Adopted IEC 335-2-40:1992 with modifications) / Securite des appareils electrodomestiques et
$31.5
CAN/CSA E60691-08 (R2012)
Published Date: 02/01/2008
Thermal-Links - Requirements and Application Guide (Adopted CEI/IEC 60691:2002 + Amendment 1:2006, third edition, 2002-12, with Canadian deviations) | Protecteurs thermiques - Prescriptions et guide d'application (norme CEI/IEC 60691:2002 + Amendement 1:2006 adoptee, troisieme edition, 2002-12, avec
$87.9
CAN/CSA B64.1.3-04
Published Date: 05/01/2005
Vacuum Breakers, Spill-Resistant Pressure Type (SRPVB)
$9.6

Best-Selling Products